Description
Technical data
Chemical-Physical characteristics (20ºC – 60% R.H.) |
|||
Specific gravity comp. A | 1,040 g/cm3 | Viscosity comp. A FORD 4 | 28’’ |
Specific gravity comp. A | 1,070 g/cm3 | Viscosity comp. B FORD 4 | 18’’ |
Specific gravity mix | 1,045 g/cm3 | pH | 7,0 |
Mixing ratios and Times (20°C – 60% U.R.) |
|||
Mixing ratio | 10:1 | Touch dry | 1 h |
Pot-life | 8 h | Sanding | 4-5 h |
Dust dry | 15^27 | Advised dilution | 5-10% water |
Technical characteristics (20°C – 60% U.R.) |
|||
Coverage | 12-14 m2 /kg | VOC content of pure prod. | < 140 g/l |
Application temp. | > + 10° | Subcat of the product. in accordance with Dir.Eur.42/2004 and specific VOC content limits. |
Cat.A/j (WB): 140 g/l (jan2007) 140 g/l (jan2010) |
Storage and labeling |
|||
Storage (original unopened packaging at amb. temp.) |
12 months (Protect from freeze) |
Symbols of danger | NONE |
Tools Cleaning |
Clean the roll just after use with water and soap or ADDITIVO S/43 using if possible a ^27roll-squeezer^27 until no more milky liquid drips out. If possible rinse finally in streaming water. |
||
Packaging |
Comp.A: canisters of 5 or 10 lt Comp.B: canisters of 0,5 or 1 lt |
Application
Sand the floor and in necessary fill the gaps using a water-based filler like IDROSTUCCO RS/30 or the ready to use PRONTOSTUCCO RS/40 or a solvent-based one like LEGASTUCCO RS/20; complete sanding operations with a 120-150 grit sized sandpaper and clean the surface.
Mix the two components respecting the right mixing ratio (10:1), wait from 10 to 20 minutes to permit a pre-reaction then apply a coat of IDROFONDO MITO by roll.
Note. For a correct mixing it is recommend to pour B comp. into A comp. slowly and under stirring, if possible using mechanical mixer; in this way the coat appearance is optimized. When the seal is completely dry (4-5 hours) sand using a very fine sandpaper (180-220 grit sized). Complete the coating cycle applying one or two hands of water-based or solvent-based varnish, single or two components.
Notes
- In case of a mixed cycle (that is when a solvent-based varnish is used on) it is very important not to break up the water-based seal during sanding; avoiding a not continuous and homogeneous wood tonalization.
- We advice to not coat in two different step the perimeter and the rest of the floor: instead we recommend to treat small zones of the perimeter and than immediately varnish adjacent area.
Safety rules
FOR PROFESSIONAL USE ONLY. Strictly respect the information reported on the labels and consult safety data sheets before use.
Disposing of waste
Dispose not used product and empty containers in accordance of local in force regulations.